NOTES, CAUTIONS AND WARNINGS
Installer should pay particular attention to the words:
NOTE, CAUTION, and WARNING. Notes
are intended to
clarify or make the installation easier. Cautions
are given to
prevent equipment damage. Warnings
are given to alert
installer that personal injury and/or equipment damage
may result if installation procedure is not handled properly.
INSTALLATION
MANUAL
CAUTION: READ ALL SAFETY GUIDES BEFORE YOU
BEGIN TO INSTALL YOUR UNIT.
SAVE THIS MANUAL
035-18496-000-C-1102
SPLIT-SYSTEM
(AIR COOLED)
EVAPORATOR BLOWER
MODELS: LB300
LB360
LB480
LB600
CONTENTS
GENERAL....................................4
REPLACEMENTPARTS........................4
INSPECTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
INDOOR PRODUCT NOMENCLATURE . . . . . . . . . . . . 5
UNITINSTALLATION..........................11
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
See the following page for a complete Table of Contents.
Vedere la pagina 0
1 2 3 4 5 6 ... 31 32

Sommario

Pagina 1 - INSTALLATION

NOTES, CAUTIONS AND WARNINGSInstaller should pay particular attention to the words:NOTE, CAUTION, and WARNING. Notesare intended toclarify or make the

Pagina 2 - TABLE OF CONTENTS

035-18496-000-C-110210 UnitaryProductsGroupFIGURE 6 - VERTICAL AIRFLOW ARRANGEMENTSFIGURE 7 - HORIZONTAL AIRFLOW ARRANGEMENTSAIRAIRBLOWER1VERTICAL ARR

Pagina 3 - LIST OF TABLES

035-18496-000-C-1102Unitary Products Group 11LB600 AIR DISCHARGEThe LB600 blower and coil section are shipped separatelyand must be joined in the fiel

Pagina 4 - INSPECTION

035-18496-000-C-110212 UnitaryProductsGroupMOUNTINGThe evaporator blower may be suspended from the joists withisolation type hangers or hooks. Suspens

Pagina 5 - INDOOR PRODUCT NOMENCLATURE

035-18496-000-C-1102Unitary Products Group 13FIGURE 9 - DETAILS FOR SECURING BOTTOM MOUNTING SUPPORTS3NOTE: The following illustration shows how the

Pagina 6 - TABLE 2: PHYSICAL DATA

035-18496-000-C-110214 UnitaryProductsGroupThe weights for the LB600 shown in 11 include only the evap-orator coil section, the blower section with a

Pagina 7

035-18496-000-C-1102Unitary Products Group 15DUCT CONNECTIONSDuctwork should always be suspended with hangers or sup-ported by legs. It should never b

Pagina 8

035-18496-000-C-110216 UnitaryProductsGroupRETURN AIR DUCT ANGLESReturn air duct angles are shipped turned in. They areintended to be unscrewed and tu

Pagina 9 - AIR DISCHARGE CONVERSION

035-18496-000-C-1102Unitary Products Group 17Suitable hangers, brackets or clamps should support therefrigerant lines.Braze all copper-to-copper joint

Pagina 10 - VERTICAL ARRANGEMENTS

035-18496-000-C-110218 UnitaryProductsGroupPUMP OUTThe pump out function is a standard feature on the 25 to 50ton systems. The pump out circuit is act

Pagina 11 - UNIT INSTALLATION

035-18496-000-C-1102Unitary Products Group 19Check belt tension. Drive packages are supplied with fiber-glass belts that must be properly tensioned at

Pagina 12 - TABLE 4: CORNER WEIGHTS

035-18496-000-C-11022 UnitaryProductsGroupTABLE OF CONTENTSGENERAL ...4NOTES, CAUTIONS AND WARNINGS . . . . . . . .

Pagina 13 - UNIT SUPPORTED FROM BELOW

035-18496-000-C-110220 UnitaryProductsGroupMAINTENANCEFilters must be cleaned or replaced as often as necessary toassure good airflow and filtering ac

Pagina 14

035-18496-000-C-1102Unitary Products Group 21TABLE 10: FAN PEFORMANCE DATA - 25 TONRPMCFM8,000 9,000 10,000 11,000 12,000SP BHP kW SP BHP kW SP BHP kW

Pagina 15 - DUCT CONNECTIONS

035-18496-000-C-110222 UnitaryProductsGroupFIGURE 17 - UNIT DIMENSIONS - LA300, LB360, LB480AIROUTAIROUTAIRINAIRIN5/85/85/8 PANEL5/8 BOTTOMPANEL7/8 KN

Pagina 16 - REFRIGERANT MAINS

035-18496-000-C-1102Unitary Products Group 23FIGURE 20 - LA300 PIPING CONNECTIONSFIGURE 21 - LB360 PIPING CONNECTIONSSUCTIONLIQUIDLIQUID (SYS. #1)LIQU

Pagina 17

035-18496-000-C-110224 UnitaryProductsGroupFIGURE 23 - UNIT DIMENSIONSFIGURE 24 - LB600 PIPING CONNECTIONS - END PANEL DETAIL6.7"13.5"6.0&qu

Pagina 18 - RO TATIO N

035-18496-000-C-1102Unitary Products Group 25To check the supply air CFM after the initial balanc-ing has been completed:1. Drill two (2) 5/16-inch ho

Pagina 19

035-18496-000-C-110226 UnitaryProductsGroupFIGURE 26 - 25-TON PRESSURE DROP VS. CFM ACROSS INDOOR COIL25-tonPressure Drop Across Indoor Coil0.000.100.

Pagina 20 - MAINTENANCE

035-18496-000-C-1102Unitary Products Group 27FIGURE 28 - 40 TON - PRESSURE DROP VS. CFM ACROSS INDOOR COIL (DOMESTIC)40-tonPressure Drop Across Indoor

Pagina 21 - Unitary Products Group 21

035-18496-000-C-110228 UnitaryProductsGroupFIGURE 30 - INDOOR UNIT WIRING DIAGRAM LB360, 480 & 600

Pagina 22 - 22 UnitaryProductsGroup

035-18496-000-C-1102Unitary Products Group 29FIGURE 31 - INDOOR WIRING DIAGRAM LA300

Pagina 23 - Unitary Products Group 23

035-18496-000-C-1102Unitary Products Group 3LIST OF TABLESTbl.# Pg.#1 UNIT APPLICATION DATA . . . . . . . . . . . . . . . . . . . . . 52 PHYSICALDATA

Pagina 24 - Condensate

035-18496-000-C-110230 UnitaryProductsGroup

Pagina 25

035-18496-000-C-1102Unitary Products Group 31

Pagina 26 - 26 UnitaryProductsGroup

Subject to change without notice. Printed in U.S.A. 035-18496-000-C-1102Copyright © by Unitary Products Group 2002. All rights reserved. Supersedes: 0

Pagina 27 - Unitary Products Group 27

035-18496-000-C-11024 UnitaryProductsGroupGENERALThe LA and LB evaporator units are designed for use with theHA/HB Series condensing units.Units are d

Pagina 28 - 28 UnitaryProductsGroup

035-18496-000-C-1102Unitary Products Group 5NOTE: LB600 Indoor Unit matches with both HB480and HB600 Outdoor Condensing Units formaximum efficiency.IN

Pagina 29 - Unitary Products Group 29

035-18496-000-C-11026 UnitaryProductsGroupTABLE 2: PHYSICAL DATADESCRIPTIONMODELLA300 LB360 LB480 LB600EVAPORATORCOILRows Deep X Rows High 4 x 40 4 x

Pagina 30 - 30 UnitaryProductsGroup

035-18496-000-C-1102Unitary Products Group 7BLOWER MOTOR MOUNTING LOCATIONSUnits are shipped from the factory less motor and drives. Theblower motor a

Pagina 31 - Unitary Products Group 31

035-18496-000-C-11028 UnitaryProductsGroupMOTOR MOUNT ARRANGEMENTSThe motor mounting arrangement can be changed to allowmotor access based on the airf

Pagina 32 - Group Drive 73069

035-18496-000-C-1102Unitary Products Group 9LB600 MOTOR ARRANGEMENTSThe LB600 unit is shipped with the motor mount in the stan-dard location as shown

Commenti su questo manuale